Data Centre Security Assessment: Hypervisors, Management Controllers and the Way Back From Ransomware
A data centre security assessment should start with the management plane: hypervisors, iLO and iDRAC controllers, and the backups you recover from. Why ransomware targets the hypervisor, what to check at each layer, and how the assessment runs.
Infrastructure Security
Moving workloads to the cloud did not empty the data centre. What stayed on premises is usually the most sensitive part of the estate: domain controllers, core databases, the backup system and the network backbone. Ransomware groups have also learned that encrypting one hypervisor takes down every virtual machine on it at once. A data centre security assessment should therefore start where an attacker would: the management plane underneath everything else.
In short. Assess the layers that control everything above them: hypervisors and their management servers, baseboard management controllers such as iLO, iDRAC and IPMI, the management network those interfaces sit on, and the backup system you would recover from. Keep management interfaces on a separate network that users cannot reach, limit who can administer hypervisors and how, and keep backups out of reach of the credentials an attacker is most likely to steal. Physical access and environmental controls still matter, but they are rarely where the worst findings are.
What a data centre security assessment covers
A useful data centre security assessment looks at physical and logical controls together, because an attacker who gets past one usually needs the other. The table shows the layers and what typically goes wrong in each.
| Layer | What is assessed | Common finding |
|---|---|---|
| Hypervisors | ESXi, Hyper-V or KVM hosts and their management servers: patch level, admin access, exposed services, hardening settings | Hosts administered with ordinary domain accounts, or months behind on patches |
| Management controllers | iLO, iDRAC and IPMI interfaces: firmware, credentials, network placement | Default or shared passwords on interfaces reachable from the user network |
| Management network | Separation from user and server networks, jump hosts, firewall rules, remote access | A "management VLAN" that any workstation can route to |
| Storage | SAN zoning, LUN masking, NAS and array admin interfaces, snapshot controls | Array admin pages on the server network with default credentials |
| Backup and recovery | Backup credentials, immutability, offline copies, restore testing | A backup server joined to the same domain it is meant to recover |
| Physical access | Access control and its logs, CCTV coverage, visitor process, rack and cage locks | Access lists that still include people who left long ago |
| Environmental | Power and cooling redundancy, fire suppression, monitoring | Redundancy designed but never tested under load |
Why attackers go for the hypervisor
Encrypting servers one at a time is slow and noisy. Encrypting the hypervisor's datastores stops every virtual machine on that host in one step, including the ones with endpoint protection the attacker never had to touch. Recent campaigns show three different ways in.
Through an exposed service
In February 2023 the ESXiArgs campaign encrypted internet-exposed ESXi servers running unpatched, out-of-date versions; CISA and the FBI reported that its operators had compromised over 3,800 servers globally. The intrusions were widely attributed to CVE-2021-21974, a flaw in the OpenSLP service patched in February 2021, and CISA's advice included disabling the Service Location Protocol (SLP) service.
Through the directory
In July 2024 Microsoft reported that ransomware operators including Storm-0506, Storm-1175, Octo Tempest and Manatee Tempest were exploiting CVE-2024-37085 on domain-joined ESXi hosts. Members of a directory group named "ESX Admins" were given full administrative access to the host, so an attacker who could create that group in Active Directory became a hypervisor administrator. Microsoft linked the technique to Akira and Black Basta ransomware deployments. Broadcom fixed it in ESXi 8.0 Update 3, and its knowledge base lists the host settings that turn the behaviour off on versions that will not be fixed.
From inside a virtual machine
In March 2025 Broadcom disclosed three ESXi vulnerabilities, CVE-2025-22224, CVE-2025-22225 and CVE-2025-22226, that were already being exploited. Together they let an attacker with administrator rights inside a virtual machine break out to the host, and CISA added all three to its Known Exploited Vulnerabilities catalogue the same day. The management server is a target too: in August 2026 CISA added CVE-2026-59310, a critical, remotely exploitable vCenter flaw disclosed by Broadcom in July, and later marked it as used in ransomware campaigns.
The lesson is not about one product. Whatever hypervisor you run, the questions are the same: who can administer it, from where, how quickly it is patched, and what an attacker who already holds a domain admin account can do to it.
One attack path, step by step
Public advisories from Microsoft and CISA describe the same sequence again and again. The path below is a composite of those patterns rather than a single incident, with the control that breaks each step.
| Stage | What the attacker does | Control that breaks it |
|---|---|---|
| Foothold | Phishing or a stolen password gives access to one user workstation | MFA, endpoint detection, no local admin rights for users |
| Directory control | Credential theft escalates to a domain admin account | Tiered administration and privileged access workstations |
| Hypervisor control | Directory rights are turned into hypervisor admin rights, for example through the ESX Admins group or management server single sign-on | Hosts that do not trust directory groups by default, dedicated hypervisor admin accounts with MFA, alerts on admin group changes |
| Removing the way back | Backup jobs and storage snapshots are deleted through consoles that trust the same directory | Separate backup credentials, an immutable or offline copy, protected snapshots |
| Impact | Datastores on every host are encrypted in one step | A separate management network, lockdown mode, execInstalledOnly, logs sent off the host |
| Recovery | The organisation tries to restore and finds out what is left | Tested, timed restores from a copy the attacker could not reach |
Hypervisor hardening: what we check
| Check | What good looks like |
|---|---|
| Patch level | Hosts and management servers on a supported version, with exploited vulnerabilities patched within days rather than the next quarterly window |
| Where it can be administered from | Host and management server interfaces reachable only from the management network, never from user networks or the internet |
| Who can administer it | Named, dedicated admin accounts with MFA on the management server; directory groups with host admin rights known, owned and monitored |
| Direct host access | Lockdown mode on, so hosts are managed through the management server rather than directly; in strict mode the host console (DCUI) is disabled as well. SSH and the ESXi Shell off, as they are by default, except during supervised maintenance |
| Unneeded services | Services such as SLP disabled where they are not used, and the host firewall restricting the rest |
| Code that can run on the host | On ESXi, the execInstalledOnly setting lets only binaries installed as part of a package run on the host. Its runtime form is on by default from ESXi 8.0; on earlier versions it has to be enabled, and with Secure Boot and a TPM it can be enforced at every boot. It does not stop interpreted scripts, so it complements access control rather than replacing it |
| Logging | Host and management server logs sent off the host to a central system, so they survive the host being encrypted |
| Management server backups | The management server's own configuration backed up and restorable, because rebuilding clusters without it is slow |
Hypervisors that run domain controllers need particular care. Microsoft's guidance is that you must manage the host where you run virtual domain controllers "as carefully as you would a writeable DC". In tiering terms, that host and whatever manages it belong with the directory itself. It also helps to keep at least one domain controller that does not depend on the same virtualisation platform, so the directory survives the loss of the platform.
Baseboard management controllers: the server's second computer
Almost every server has a baseboard management controller (BMC): HPE iLO, Dell iDRAC, or a generic IPMI interface. It runs independently of the operating system and can power the server on and off, open a remote console, mount virtual media and update firmware. Whoever controls it controls the server, below the reach of any security software running on it.
BMCs are also among the most neglected devices in a data centre. They are set up once at installation and rarely revisited, so assessments find default or shared passwords, firmware years out of date, and interfaces on the same network as ordinary servers or users.
- IPMI has a protocol-level weakness. The IPMI 2.0 specification has the controller send a salted hash of a user's password before the client has authenticated, so anyone who can reach the interface and guess a valid username can collect a hash to crack offline. Some implementations have also accepted any password when "cipher zero" is enabled.
- BMC firmware is a target in its own right. In December 2021, researchers at the Iranian security firm Amnpardaz reported a rootkit, dubbed iLOBleed, hidden in HPE iLO firmware. It was used to wipe servers, faked firmware upgrades so that it survived them, and persisted across operating system reinstalls. HPE said it exploited flaws patched in 2018.
- Government guidance is clear. In June 2023, CISA and the NSA published joint guidance on hardening BMCs, noting that "hardened credentials, firmware updates, and network segmentation options are often overlooked, leading to a vulnerable BMC." Their advice: change default credentials as soon as possible, limit the systems that can talk to BMCs to a dedicated administrative network, and check for firmware updates routinely. It follows that a BMC should never be reachable from the internet.
A BMC hardening baseline to assess against:
- Unique credentials for every controller, stored in a password vault, with factory defaults removed.
- Dedicated management ports connected only to the management network, never to user or server networks, and never reachable from the internet.
- Unused protocols disabled: IPMI over LAN where it is not needed, legacy SNMP versions, and unencrypted web or console access.
- Firmware on a regular update cycle, checked against the vendor's security advisories.
- Remote console and virtual media restricted to named administrators, with logs forwarded to a central system.
The management network
Hypervisor, BMC, storage and network device interfaces should all sit on a management network that ordinary users and servers cannot reach. In assessments this is often true on the diagram and false in practice: a firewall rule added for a contractor, a route left from a migration, or an admin's laptop that sits on both networks.
The test is direct. From a user workstation and from an ordinary server, try to reach the management interfaces. Then check how administrators actually get in: through a hardened jump host with MFA, or straight from their everyday laptop. A firewall review of the rules into the management network usually explains every gap the test finds, and a network architecture review designs the separation properly.
Detecting attacks on the management plane
Most of these attacks leave signals in places a SOC does not watch by default. Make sure these reach your SIEM, and that the logs leave the host before anything can delete them.
| Signal | Where it shows up | Why it matters |
|---|---|---|
| A group named "ESX Admins" created or changed | Active Directory security events 4727, 4731 and 4754 (group created) and 4728, 4732 and 4756 (member added) | The CVE-2024-37085 technique depends on it |
| SSH or the ESXi Shell enabled | Host and management server events | Rarely legitimate outside planned maintenance |
| Lockdown mode turned off | Management server events | Often comes before direct access to hosts |
| Many virtual machines powered off, or snapshots deleted at once | Management server events | A common step just before encryption |
| BMC logins from unusual sources, virtual media mounted, firmware changed | BMC logs sent by syslog | Control below the operating system |
| Backup jobs, retention or immutability settings changed | Backup console audit log | Attackers remove the way back first |
| Storage volumes or snapshots deleted | Array audit log | Destroys data without encrypting anything |
Our guide to detection engineering covers how to turn signals like these into detections that stay useful.
Storage: where the data actually lives
Storage arrays and NAS devices hold the virtual machine disks, file shares and often the backups. Check that SAN zoning and LUN masking limit each host to the storage it needs, that array and NAS admin interfaces are on the management network with individual accounts, and who can delete snapshots. An attacker with array admin access does not need to encrypt anything: deleting volumes and snapshots is enough. Some arrays can protect snapshots from deletion for a set period, or require a second administrator to approve it; where that exists, turn it on for the volumes that hold virtual machines and backups.
Backups: keep the way back out of reach
Ransomware operators look for the backups early, because recovery without paying depends on them. The most common weakness is shared trust: a backup server joined to the production domain, backup consoles administered with domain admin accounts, or backup storage that the same credentials can delete.
CISA's #StopRansomware Guide warns that "many ransomware variants attempt to find and subsequently delete or encrypt accessible backups", and recommends keeping offline, encrypted backups of critical data and regularly testing their availability and integrity. Backup vendors say the same about trust: Veeam's security guidance puts it as "a data protection system should not rely on the environment it is meant to protect in any way!" In practice, that means at least one copy that cannot be changed or deleted for a set period even by an administrator, backup infrastructure with its own credentials outside the production directory, and restores that are tested, timed and recorded. Our guide to setting RTO and RPO you can meet after ransomware covers how fast those restores need to be, and a ransomware readiness assessment tests whether the whole recovery chain holds when the hypervisor is the target.
Physical and environmental controls
Physical access still bypasses most logical controls: someone in the room can plug into a console port, remove a disk or attach a device to the management network. Assess access control configuration and its logs, CCTV coverage and blind spots, the visitor and contractor process, and rack and cage locks. ISO/IEC 27001:2022 groups its 93 Annex A controls into four themes, and 14 of them are physical controls covering perimeters, entry, secure areas, monitoring, equipment, utilities and cabling, so physical findings map directly onto them.
In practice, physical testing means:
- Comparing the access control list with HR records, to find leavers and contractors whose badges still work.
- Reviewing access logs for out-of-hours entry and doors held or forced open.
- Observing, with authorisation, whether tailgating through controlled doors is challenged.
- Mapping CCTV coverage against entrances, cages and rack rows, and checking how long footage is kept.
- Checking how rack keys, spare badges and removable media are controlled, and how failed disks are destroyed.
In a colocation facility, physical security is shared. The provider is responsible for the building and its perimeter; you are responsible for your cage, your equipment and who you authorise to enter. Use the provider's independent audit reports for their side, and assess your own.
Environmental resilience is a separate question. Uptime Institute's Tier classification, from Tier I to Tier IV, rates a facility's site infrastructure for availability, and ANSI/TIA-942, revised as TIA-942-C in 2024, sets infrastructure requirements for data centres. A high tier rating tells you the power and cooling are designed to keep running; it does not tell you the servers inside are secure.
Redundancy is usually described as N+1, one more component than the load needs, or 2N, a complete duplicate of every component. The question to assess is whether it has been tested: would the loss of one power feed, one cooling unit or one network path actually be absorbed? That is part of BCDR planning, and it is worth testing before an incident does it for you.
How the assessment runs
Step 1 — Documents and inventory
Network diagrams, the host and BMC inventory, the access control policy, backup design and recent restore evidence. The gaps between documents and reality are part of the findings.
Step 2 — Configuration review
Hypervisors, management servers, BMCs, storage and backup systems reviewed against vendor hardening guidance and CIS Benchmarks where they exist.
Step 3 — Reachability testing
From user and server networks, attempt to reach management interfaces, and test the credentials and exposed services found there.
Step 4 — Physical walkthrough
Access control, CCTV coverage, visitor handling, rack security and environmental systems, checked on site.
Step 5 — Recovery evidence
Review restore test records, or witness a restore, to confirm the recovery the plan promises is achievable.
Step 6 — Report and retest
Findings ordered by how much they would let an attacker control, with specific fixes, mapped to ISO 27001 and SOC 2 where you need the evidence, then a retest.
Preparing for the assessment
- Network diagrams, including the management network and how administrators reach it.
- An inventory of hosts, management servers, BMCs, storage arrays and backup systems, with versions.
- Read-only access to the management server, backup console and storage management for configuration review.
- The physical access control policy, the current access list and recent access logs.
- Backup design documents and the records of recent restore tests.
- For colocation, the provider's latest independent audit reports.
Data centre security checklist
| Control | Why it matters |
|---|---|
| Management network unreachable from users | Most hypervisor and BMC attacks need network access to the interface first |
| Hypervisor admin rights tightly held | A stolen domain admin account should not equal every virtual machine |
| Exploited hypervisor flaws patched in days | Ransomware groups use them within weeks of disclosure, sometimes before |
| Unique BMC credentials and current firmware | A BMC controls the server below its security software |
| Backups outside the production domain, with an immutable copy | The way back must survive the credentials an attacker steals |
| Restores tested and timed | An untested backup is a hope, not a plan |
| Logs leave the host | Evidence on an encrypted host is gone |
| Physical access reviewed against HR records | Leavers with working badges are a common, easy finding |
Frequently Asked Questions
Click any question to expand the answer.
QWhat does a data centre security assessment cover?
Hypervisors and their management servers, baseboard management controllers such as iLO, iDRAC and IPMI, the management network, storage, backup and recovery, physical access controls and environmental systems. A good assessment covers physical and logical controls together, because an attacker who gets past one usually needs the other.
QWhy do ransomware groups target VMware ESXi?
Because encrypting the hypervisor stops every virtual machine on it at once. CISA's #StopRansomware Guide notes that ransomware strategies have begun targeting ESXi servers, hypervisors and other centralised systems, "which enables fast encryption of the infrastructure at scale."
QWhat is CVE-2024-37085?
A VMware ESXi vulnerability affecting hosts joined to Active Directory: members of a group named "ESX Admins" received full administrative access, so an attacker who could create that group became a hypervisor administrator. Microsoft reported ransomware operators exploiting it in July 2024. Broadcom fixed it in ESXi 8.0 Update 3 and documented settings to disable the behaviour on other versions.
QShould ESXi hosts be joined to Active Directory?
There is no single right answer, but joining hosts means anyone who controls the directory can potentially control the hypervisors. If you do join them, apply Broadcom's recommended settings for the admin group, monitor creation of and changes to that group, and keep directory admin rights tightly held. Many organisations administer hosts only through the management server with dedicated accounts.
QWhat is a baseboard management controller?
A small computer built into a server, such as HPE iLO, Dell iDRAC or a generic IPMI interface, that runs independently of the operating system. It can power the server on and off, open a remote console, mount virtual media and update firmware, so whoever controls it controls the server.
QHow should iLO, iDRAC and IPMI interfaces be secured?
Change default credentials and use unique ones per device, keep firmware current, put the interfaces on a dedicated management network that only administrators can reach, and never expose them to the internet. Where IPMI is not needed, disable it, because the protocol lets an attacker collect password hashes.
QHow should backups be protected from ransomware?
Keep at least one offline or immutable copy, run backup infrastructure with credentials that are separate from the production directory, restrict who can delete backups or snapshots, and test restores regularly with recorded timings.
QCan a data centre assessment cover colocation facilities?
Yes. In colocation, physical security is shared: the provider is responsible for the building and its perimeter, and the customer for its cage, equipment and authorised visitors. The customer's side is assessed directly, and the provider's independent audit reports cover the rest.
QWhich logs should we monitor for attacks on hypervisors?
Creation of or changes to hypervisor admin groups in Active Directory, SSH or shell access being enabled on hosts, lockdown mode being turned off, mass virtual machine power-offs or snapshot deletions, unusual BMC logins and firmware changes, backup retention changes, and storage snapshot or volume deletions. Send them to the SIEM so they survive the host.
QWhat is the difference between N+1 and 2N redundancy?
N+1 means one more component than the load needs, such as one spare cooling unit. 2N means a complete duplicate of every component, such as two independent power paths. Either only helps if it has been tested under real load.
QHow does a data centre assessment map to ISO 27001 and SOC 2?
Physical findings map to the 14 physical controls in ISO/IEC 27001:2022 Annex A, and logical findings to its technological controls. For SOC 2, they map to the physical access and availability criteria, which gives auditors evidence for both frameworks from one assessment.
QHow often should a data centre be assessed?
A full assessment once a year and after major changes, such as a new site, a hypervisor platform change or a backup redesign, is a sensible rhythm. Hypervisor and BMC patching, admin group membership and restore tests need checking continuously in between.
Related reading
For the directory that so often holds the keys to the hypervisor, see Active Directory security: hardening against modern attacks. For the wider ransomware picture, the ransomware defence playbook for India. For the network devices at the edge of the same estate, what recent edge-device zero-days say about your perimeter.
Sources
- CISA and FBI, AA23-039A: ESXiArgs ransomware virtual machine recovery guidance.
- Microsoft, Ransomware operators exploit ESXi hypervisor vulnerability for mass encryption.
- Broadcom, Knowledge base article 369707: ESXi Active Directory admin group settings.
- Broadcom, VMSA-2025-0004: VMware ESXi, Workstation and Fusion updates.
- CISA, Known Exploited Vulnerabilities catalogue.
- BleepingComputer, CISA: critical VMware vCenter RCE flaw now exploited by ransomware gangs.
- CISA and NSA, Joint guidance on hardening baseboard management controllers.
- Rapid7, A penetration tester's guide to IPMI and BMCs.
- The Record, Threat actor uses HP iLO rootkit to wipe servers.
- CISA, #StopRansomware Guide.
- Veeam, Security best practices: workgroup or domain?.
- Uptime Institute, Explaining Uptime Institute's Tier classification system.
- TIA, ANSI/TIA-942 data centre infrastructure standard.
- Microsoft, Virtualizing domain controllers using Hyper-V.
Adayptus Consulting
Infrastructure Security, Adayptus
Adayptus Consulting Private Limited is a cybersecurity consultancy based in Noida, India, assessing physical and logical data centre controls together, for on-premises and colocation facilities.
On This Page
- What a data centre security assessment covers
- Why attackers go for the hypervisor
- One attack path, step by step
- Hypervisor hardening: what we check
- Baseboard management controllers: the server's second computer
- The management network
- Detecting attacks on the management plane
- Storage: where the data actually lives
- Backups: keep the way back out of reach
- Physical and environmental controls
- How the assessment runs
- Preparing for the assessment
- Data centre security checklist
- Frequently Asked Questions
- Related reading
- Sources